HTML 5
ZERO-FOOTPRINT
DICOM VIEWER

MedDream is a web-based DICOM Viewer for PACS Server that is aimed at making diagnoses, viewing, archiving and transmitting medical images. The DICOM Viewer can be integrated into any PACS system including MedDream PACS, PacsOne, dcm4chee, Orthanc, Conquest, ClearCanvas, etc.

Vendor neutral, ready to integrate into the Enterprise DICOM Viewer

slider-image
slider-image
slider-image

COMPATIBLE WITH OPEN SOURCE

Features

Features toggle

ECG & ULTRASOUND

The MedDream DICOM Viewer provides not only standard image manipulation tools, but also a way to read, manipulate and interpret electrocardiography (ECG) data.

ECG manipulation tools are all presented in an innovative zoom model, which allows to zooming in/out, measure and quantify the ECG data:

icon

Area calculation indicating beats per minute, time, millivolt (mV, s, bpm);

icon

QT interval - the RR interval is calculated as well as QT and the QTc (based on Bazett’s formula);

icon

Measure heart rate (HR) and compare its interval variance over the ECG;

icon

Measure the QRS electrical heart axis;

icon

Velocity Time Integral (VTI) measurement on ultrasound studies that can quantify the trace of the Doppler flow profile;

icon

Review an ultrasound (US) machine-generated report;

icon

Comparison of two or more ECGs by normalizing and then overlaying them on one another;

icon

Up to 12 ECGs may be opened at once.

Supported ECG devices: 

  • Mortara
  • Custo med
  • Schiller
  • GE
  • Other 12 lead DICOM ECG (Little Endian) or devices that, in conjunction with a gateway, can provide such data.

Other parties’ brand names, with ownerships belonging to Mortara Instrument, custo med GmbH, SCHILLER AG, GE Healthcare, are not authorized by, sponsored by or associated with the MedDream trademark owner.

MedDream can be used to measure the volume of a 2D image by using Simpson’s approximation rule; the 2D area is spun around a selected axis to form a 3D shape and the volume is measured. This technique allows volume measurements of a heart in a 2D Computed Radiography image.

MedDream supports measurement of the Velocity Time Integral (VTI) on ultrasound (US) studies that can quantify the trace of the Doppler flow profile.

MedDream web dicom viewer ECG and US
MedDream web dicom viewer ECG and US mouse
MedDream web dicom viewer ECG and US mobile
previous arrowprevious arrow
next arrownext arrow
Slider

For more information, download the MedDream DICOM Viewer brochure or read more about the MedDream WEB DICOM Viewer.